{"product_id":"ppp-beckman-coulter-optima-xl-series-floor-ultracentrifuge","title":"Beckman Coulter Optima XL Series Floor Ultracentrifuge","description":"\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eOverview of Beckman Coulter Optima XL Series Floor Ultracentrifuge\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe Optima XL Series is a preparative ultracentrifuge that is useful in separation of particles with maximum speeds of 80,000 rpm for the XL-80K, 90,000 rpm for the XL-90K, and 100,000 rpm for the XL-100K. Designed for continuous flow of operation, the Optima XL series is microprocessor-controlled with interactive menu operation. The series is also equipped with the Efficient Sedimentation Program (ESP) that simulates the formation of the gradient and separation of samples in a wide selection of Beckman Coulter rotors.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\n\u003cspan\u003eView in stock used floor centrifuge for sale \u003c\/span\u003e\u003ca href=\"https:\/\/newlifescientific.com\/collections\/floor-centrifuges\"\u003e\u003cspan\u003ehere\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e. Need assistance? \u003c\/span\u003e\u003ca href=\"https:\/\/newlifescientific.com\/pages\/contact-us\"\u003e\u003cspan\u003eGet in touch with us\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e today.\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eBeckman Coulter Optima XL Series Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eHere are the key features of the Optima XL Series XL-80K, XL-90K, and XL-100K:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" style=\"padding-left: 40px;\"\u003e\u003cstrong\u003e•  Program Library:\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003eThe Optima XL series has a program library that can hold up to 9 standard programs with a multi-step sequential program, and rotor usage logging. The Optima XL series also has a built-in printer for printing rotor and run data.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" style=\"padding-left: 40px;\"\u003e\u003cspan\u003e\u003cstrong\u003e• Standby Mode:\u003c\/strong\u003e \u003c\/span\u003e\u003cspan\u003eThe Optima XL series has a Standby Mode feature wherein the screen goes blank until the unit is returned back to operational condition by pressing any key on the control panel. The Standby Mode only requires minimal power to keep the ultracentrifuge in a ready state.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" style=\"padding-left: 40px;\"\u003e\u003cstrong\u003e• Rotor Chamber: \u003c\/strong\u003e\u003cspan\u003eThe Optima XL series’ rotor chamber has a solenoid interlock system that prevents it from being opened during operation. It can only be opened when the vacuum is off, the power is on, and the chamber is at atmospheric pressure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" style=\"padding-left: 40px;\"\u003e\u003cstrong\u003e• Vacuum System: \u003c\/strong\u003e\u003cspan\u003eThe Optima XL series is equipped with a mechanical vacuum pump using a diffusion pump to reduce the chamber pressure. It is also equipped with a purge system that removes significant amounts of vacuum pump and chamber moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" style=\"padding-left: 40px;\"\u003e\u003cstrong\u003e• Temperature Control System: \u003c\/strong\u003e\u003cspan\u003eThe Optima XL series has a solid state thermoelectric refrigeration and heating system that doesn’t need freon nor water as coolant.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" style=\"padding-left: 40px;\"\u003e\u003cstrong\u003e• Overspeed System: \u003c\/strong\u003e\u003cspan\u003eThe overspeed system of the Optima XL series is designed for safety so that the rotor does not exceed its maximum speed with an overspeed disk in each rotor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" style=\"padding-left: 40px;\"\u003e\u003cspan\u003e\u003cstrong\u003e• Rotor Energy System:\u003c\/strong\u003e \u003c\/span\u003e\u003cspan\u003eIf the calculated rotor energy set is identified excessive, the Optima XL series’ rotor energy system recalculates and uses a permitted set speed to avoid rotor damage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" style=\"padding-left: 40px;\"\u003e \u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\n\u003cspan\u003eBeckman Coulter Optima XL Series Floor Ultracentrifuge Specifications\u003c\/span\u003e\u003cspan\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cdiv align=\"left\" dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003ca href=\"https:\/\/newlifescientific.com\/collections\/beckman-coulter\"\u003e\u003cspan\u003eBeckman Coulter\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003ca href=\"https:\/\/newlifescientific.com\/collections\/beckman-coulter\"\u003e\u003cspan\u003eBeckman Coulter\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003ca href=\"https:\/\/newlifescientific.com\/collections\/beckman-coulter\"\u003e\u003cspan\u003eBeckman Coulter\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan style=\"color: rgb(59, 185, 136);\"\u003e\u003cstrong\u003eXL-80K\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan style=\"color: rgb(59, 185, 136);\"\u003e\u003cstrong\u003eXL-90K\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan style=\"color: rgb(59, 185, 136);\"\u003e\u003cstrong\u003eXL-100K\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSpeed Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e1,000 to 80,000 rpm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e1,000 to 90,000 rpm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e1,000 to 100,000 rpm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e \u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e0°C to 40°C with 1°C increments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e0°C to 40°C with 1°C increments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e0°C to 40°C with 1°C increments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e220\/240V, 50\/60Hz, 20A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e200-240V, 50\/60Hz, 20A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e200\/240V, 50\/60Hz, 20A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e37 x 26.5 x 47.5 in\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e37 x 26.5 x 47.5 in\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e37 x 26.5 x 48 in\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u003cb\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eOur Optima XL Series Testing Process\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp style=\"padding-left: 40px;\" dir=\"ltr\"\u003e\u003cspan\u003e1. Centrifuge technician pre-tests the unit’s (1) speed sometimes to maximum speed for a few minutes, (2) refrigeration (if equipped), (3) spinning if they spin up and spin down properly, (4) checks the buttons, switches, timers if they are all working. Necessary parts for repair are ordered.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\" dir=\"ltr\"\u003e\u003cspan\u003e2. Once any parts come in for the unit, or they’re working, the centrifuge technician performs any necessary repairs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\" dir=\"ltr\"\u003e\u003cspan\u003e3. The centrifuge technician runs the unit to maximum RPMs for a minimum of 1 hour while observing the refrigeration performance (if applicable). During this step, loud\/unusual noises, smells, and extra heat build up are observed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\" dir=\"ltr\"\u003e\u003cspan\u003e4. The centrifuge technician also observes the proper performance of sensors like temperature, vacuum (if equipped), rotor sensors, tach sensors, latch sensors, etc.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\" dir=\"ltr\"\u003e\u003cspan\u003e5. After a full hour run, the centrifuge technician takes a photo of the centrifuge display to be shown in the listing photos on New Life Scientific’s e-commerce platforms.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\" dir=\"ltr\"\u003e\u003cspan\u003e6. The centrifuge technician then does a thorough look over throughout the centrifuge to identify anything that is missing, loose, or damaged. The centrifuge technician follows New Life Scientific’s Centrifuge Technician Checklist at this time to make sure everything is checked accordingly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\" dir=\"ltr\"\u003e\u003cspan\u003e7. The refrigeration condenser and chassis cleaned are both handled by blowing out the unit with compressed air or dry ice blasting.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\" dir=\"ltr\"\u003e\u003cspan\u003e8. Sensors are cleaned and\/or re-installed with proper gap. Electrical connections are latched and tightened down properly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\" dir=\"ltr\"\u003e\u003cspan\u003e9. Drive mounts, drive brushes, gas springs are checked and replaced, if necessary.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\" dir=\"ltr\"\u003e\u003cspan\u003e10. The centrifuge is then cleaned and if needed, painted as well, to make sure the unit comes out as standard as we can.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e \u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eOur Centrifuge Technician Checklist\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAt New Life Scientific, our technicians test each device thoroughly before shipping to verify performance and functionality. After our centrifuge technician finishes the initial testing process, this \u003c\/span\u003e\u003cem\u003eCentrifuge Technician Checklist\u003c\/em\u003e\u003cspan\u003e is filled out to record the important information gathered throughout the repair process. This checklist will be available publicly after the unit has undergone tech completion.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0064\/4268\/0410\/files\/Blank_Ultracentrifuge_Checklist_page-0001.jpg?v=1770052869\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e \u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eBeckman Coulter Optima XL Series Ultracentrifuge Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp style=\"padding-left: 40px;\" dir=\"ltr\"\u003e\u003cstrong\u003e• Cell Biology and Biochemistry\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e- \u003c\/span\u003e\u003cspan\u003eThe centrifuge is commonly used for harvesting cells from cultures in bioprocessing, cell culture studies, and in research applications. It aids in separating proteins from other cellular components in studies related to biochemistry. It also helps isolate and concentrate RNA or DNA from biological samples.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\" dir=\"ltr\"\u003e\u003cstrong\u003e• Blood Separation\u003c\/strong\u003e\u003cspan\u003e - Centrifuges are used to separate blood components (plasma, serum, and cells) for diagnostic tests, blood banking, or plasma collection for medical treatments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\" dir=\"ltr\"\u003e\u003cstrong\u003e• \u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003eUrine and Stool Sample Analysis\u003c\/strong\u003e - \u003c\/span\u003e\u003cspan\u003eFor isolating cells, bacteria, or other particles for microbiological analysis or diagnostics.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\" dir=\"ltr\"\u003e\u003cstrong\u003e• \u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003eMicrobiological Testing\u003c\/strong\u003e - \u003c\/span\u003e\u003cspan\u003eSeparation of microorganisms from biological samples for culture or identification.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\" dir=\"ltr\"\u003e\u003cstrong\u003e• \u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003eWater Quality Testing\u003c\/strong\u003e - \u003c\/span\u003e\u003cspan\u003eUsed to separate particulates, microorganisms, or contaminants from water samples for analysis in environmental monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\" dir=\"ltr\"\u003e\u003cstrong\u003e• \u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003eViral Particle Isolation \u003c\/strong\u003e-\u003c\/span\u003e\u003cspan\u003e In research on viruses, benchtop centrifuges help isolate viral particles from cell cultures or biological samples.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\" dir=\"ltr\"\u003e\u003cstrong\u003e• \u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003eGene Therapy Applications\u003c\/strong\u003e - \u003c\/span\u003e\u003cspan\u003eIn genetic research, centrifuges assist in separating viral vectors, plasmids, or other generic materials from cultures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\" dir=\"ltr\"\u003e\u003cstrong\u003e• \u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003eNanoparticle Synthesis \u003c\/strong\u003e- \u003c\/span\u003e\u003cspan\u003eUsed for separating nanoparticles or other fine materials form solution after synthesis.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\" dir=\"ltr\"\u003e\u003cstrong\u003e• \u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003eFood and Beverage Industry \u003c\/strong\u003e- \u003c\/span\u003e\u003cspan\u003eUsed to separate fats from milk or cream during processing in the dairy industry. Used to remove pulp and other solid particles from fruit juice. In the fermentation process for beer and wine production, centrifuges help separate yeast from liquids.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\" dir=\"ltr\"\u003e\u003cstrong\u003e• \u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003eForensic Science\u003c\/strong\u003e - \u003c\/span\u003e\u003cspan\u003eIn forensic investigations, benchtop centrifuges help isolate blood components or bodily fluids for DNA extraction and analysis. Can also help to analyze drugs, poisons, or other toxic compounds.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\" dir=\"ltr\"\u003e\u003cstrong\u003e• \u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003eTeaching Tool\/Educational \u003c\/strong\u003e- \u003c\/span\u003e\u003cspan\u003eIn educational settings, benchtop centrifuges are used in laboratory classes for demonstrations on centrifugation principles and sample preparation techniques.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eContact New Life Scientific Today for Additional Information\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eOur team can help you decide which Beckman Coulter Optima XL Series Ultracentrifuge aligns best with your processing needs. \u003c\/span\u003e\u003ca href=\"https:\/\/newlifescientific.com\/pages\/contact-us\"\u003e\u003cspan\u003eContact us\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e today if you have questions or need additional specifications. You may also:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\" dir=\"ltr\"\u003e\u003cspan\u003e• Live chat with us by clicking on the icon at the lower right of your screen.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\" dir=\"ltr\"\u003e\u003cspan\u003e• Email us at \u003c\/span\u003e\u003ca href=\"mailto:cs@newlifescientific.com\"\u003e\u003cspan\u003ecs@newlifescientific.com\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\" dir=\"ltr\"\u003e\u003cspan\u003e• Call us at \u003c\/span\u003e\u003ca href=\"tel:5672102838\"\u003e\u003cspan\u003e(567)-210-2838\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Beckman Coulter","offers":[{"title":"Default Title","offer_id":49428013351140,"sku":null,"price":11275.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0064\/4268\/0410\/files\/58695857.jpg?v=1769114985","url":"https:\/\/newlifescientific.com\/products\/ppp-beckman-coulter-optima-xl-series-floor-ultracentrifuge","provider":"New Life Scientific","version":"1.0","type":"link"}