{"product_id":"ppp-microfluidics-lm10-microfluidizer-high-shear-fluid-processor-homogenizer","title":"Microfluidics LM10 Microfluidizer High-Shear Fluid Processor Homogenizer","description":"\u003cdiv class=\"subheaders\"\u003e\n\u003ch1 dir=\"ltr\"\u003e\u003cspan\u003eOverview of Microfluidics LM10 Microfluidizer High-Shear Fluid Processor Homogenizer\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe Microfluidics LM10 microfluidizer processor is pneumatically driven with a modern user interface perfect for small sample size research. The LM10 microfluidizer processor boasts its cell disruption and submicron size reduction. The LM10 operates with a pressure range of up to 23,000 psi or 1586 bar with a minimum sample size of 30 mL.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cstrong\u003eView in-stock used microfluidizers for sale \u003ca href=\"https:\/\/newlifescientific.com\/collections\/microfluidics-microfluidizer-cell-disruptor-homogenizer\"\u003ehere\u003c\/a\u003e. Need assistance? \u003ca href=\"https:\/\/newlifescientific.com\/pages\/contact-us\"\u003eGet in touch with us\u003c\/a\u003e today.\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eMicrofluidics LM10 Microfluidizer Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eHere are the top features of the Microfluidics LM10 processor:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" style=\"padding-left: 40px;\"\u003e\u003cspan\u003e\u003cstrong\u003e• \u003c\/strong\u003eIts economical air-driven intensifier pump supplies desired pressure at constant rate within the interaction chamber producing uniform product results.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" style=\"padding-left: 40px;\"\u003e\u003cspan\u003e\u003cstrong\u003e• \u003c\/strong\u003eThe LM10 achieves high-yield cell disruption and deagglomeration with tighter particle size distribution at low process pressure with real-time temperature monitoring capability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" style=\"padding-left: 40px;\"\u003e\u003cspan\u003e\u003cstrong\u003e•\u003c\/strong\u003e The LM10 is equipped with a ceramic interaction chamber, a cooling coil and bath assembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cstrong\u003eMicrofluidics LM10 Microfluidizer Specifications \u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv dir=\"ltr\" align=\"left\"\u003e\n\u003ctable style=\"width: 100.09%; height: 498.222px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"230\" style=\"width: 41.5162%;\"\u003e\n\u003ccol width=\"394\" style=\"width: 71.1191%;\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.9492px;\"\u003e\n\u003ctd style=\"height: 39.9492px;\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 39.9492px;\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003ca href=\"https:\/\/newlifescientific.com\/collections\/microfluidics\" title=\"Used Microfluidics equipment for sale at New Life Scientific\" target=\"_blank\"\u003e\u003cspan\u003eMicrofluidics\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eLM10\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.9492px;\"\u003e\n\u003ctd style=\"height: 39.9492px;\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003ePressure range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 39.9492px;\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eUp to 23,000 psi (1,546 bar)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.9492px;\"\u003e\n\u003ctd style=\"height: 39.9492px;\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMinimum sample size\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 39.9492px;\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e30 ml\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.9492px;\"\u003e\n\u003ctd style=\"height: 39.9492px;\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eFlow rate range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 39.9492px;\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eUp to 600 ml\/min\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.9492px;\"\u003e\n\u003ctd style=\"height: 39.9492px;\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003ePump actuator\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 39.9492px;\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePneumatically driven\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 69.3398px;\"\u003e\n\u003ctd style=\"height: 69.3398px;\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eAir utility requirement\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 69.3398px;\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFree mode = 57 scfm @ 120 psi (27 l\/s @ 8.3 bar)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.9492px;\"\u003e\n\u003ctd style=\"height: 39.9492px;\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eAir supply max\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 39.9492px;\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e150 psi (10.3 bar) max\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.9492px;\"\u003e\n\u003ctd style=\"height: 39.9492px;\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eNoise level\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 39.9492px;\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u0026lt;80dB TWA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.9492px;\"\u003e\n\u003ctd style=\"height: 39.9492px;\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003ePower rating\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 39.9492px;\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e100-240V, 50\/60Hz, 5A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 69.3398px;\"\u003e\n\u003ctd style=\"height: 69.3398px;\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 69.3398px;\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e17.25 x 26.58 x 18.87 in (43.8 x 67.5 x 47.9 cm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.9492px;\"\u003e\n\u003ctd style=\"height: 39.9492px;\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 39.9492px;\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e75 lb (34 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eOur Microfluidizer Testing Process\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\" style=\"padding-left: 40px;\"\u003e\u003cspan\u003e1. Microfluidizer technician inspects electrical components, verifying proper functionality. Rewiring is done if needed.\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e2. Microfluidizer technician performs a detailed inspection on the high pressure fittings, and proper tightness are ensured.\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e3. The low pressure fittings are then inspected for proper seal.\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e4. Microfluidizer technician inspects hydraulic and pneumatic systems for damage. Then the unit is turned on, to make sure it runs smoothly.\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e5. Microfluidizer technician changes hydro oil if necessary.\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e6. The unit is then run\/sterilized with denatured alcohol.\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e7. The unit is then cleaned and stainless steel is polished.\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e8. Upon purchase by the customer, plunger seal(s) are replaced, to ensure a fresh seal when the customer gets it. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\"\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eAvailable Microfluidics LM10 Microfluidizer Upgrades, Accessories, and Options\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\" style=\"padding-left: 40px;\"\u003e\u003cspan\u003e- Interaction Chamber\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e- Stainless Steel Reservoir\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e- Mechanical Pressure Gauge\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e- \u003ca href=\"https:\/\/newlifescientific.com\/products\/microfluidics-lm20-m-110eh-m-110p-processor-preventive-maintenance-toolkit?_pos=1\u0026amp;_sid=dc417f38d\u0026amp;_ss=r\" title=\"Microfluidics preventive maintenance toolkit from New Life Scientific\"\u003ePreventive Maintenance Toolkit\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e- Power Cable\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e- \u003c\/span\u003e\u003ca href=\"https:\/\/newlifescientific.com\/pages\/new-life-scientific-inc-warranty-agreement\"\u003e\u003cspan\u003e90-Day to 1-Year Warranty\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" style=\"padding-left: 40px;\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eOur Microfluidics Microfluidizer Technician Checklist\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAt New Life Scientific, our technicians test each device thoroughly before shipping to verify performance and functionality. After our microfluidizer technician finishes the initial testing process, this \u003c\/span\u003e\u003cem\u003eMicrofluidics Technician Checklist\u003c\/em\u003e\u003cspan\u003e is filled out to record the important information gathered throughout the repair process. This checklist will be available publicly after the unit has undergone tech completion. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0064\/4268\/0410\/files\/Blank_Microfluidics_Checklist_page-0001.jpg?v=1751975747\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eMicrofluidics LM10 Microfluidizer Processor Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\" style=\"padding-left: 40px;\"\u003e\u003cstrong\u003e• \u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003eCell Disruption\u003c\/strong\u003e \u003c\/span\u003e\u003cspan\u003e- This is used for breaking open cells to extract proteins, nucleic acids, and other intracellular materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" style=\"padding-left: 40px;\"\u003e\u003cstrong\u003e• \u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003eEmulsification\u003c\/strong\u003e \u003c\/span\u003e\u003cspan\u003e- Creation of stable emulsions by dispersing one liquid into another, typically with the goal of producing uniform droplets in applications like cosmetics, food, and pharmaceuticals.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" style=\"padding-left: 40px;\"\u003e\u003cstrong\u003e• Nanoparticle and Liposome Preparation\u003c\/strong\u003e\u003cspan\u003e - Formation of nanoparticles or liposomes for drug delivery, diagnostics, and other applications requiring fine particle sizes. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" style=\"padding-left: 40px;\"\u003e\u003cstrong\u003e• Homogenization\u003c\/strong\u003e\u003cspan\u003e - Ensuring uniform distribution of particles in a liquid, often for biological, food, or chemical products. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" style=\"padding-left: 40px;\"\u003e\u003cstrong\u003e• Dispersing Powders or Solids into Liquids\u003c\/strong\u003e\u003cspan\u003e - Efficiently dispersing powders or solid materials into liquids, which is crucial for making stable suspensions and slurries. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" style=\"padding-left: 40px;\"\u003e\u003cstrong\u003e• Particle Size Reduction\u003c\/strong\u003e\u003cspan\u003e - Reducing the size of particles in a sample to achieve desired size distributions, which is essential for the uniformity and quality of products in various sectors. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" style=\"padding-left: 40px;\"\u003e\u003cstrong\u003e• \u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003eVaccine and Antigen Production\u003c\/strong\u003e \u003c\/span\u003e\u003cspan\u003e- Disrupting bacterial or viral cells for vaccine preparation, enhancing the delivery of antigens in therapeutic formulations. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" style=\"padding-left: 40px;\"\u003e\u003cstrong\u003e• Bioprocessing\u003c\/strong\u003e\u003cspan\u003e - Large-scale production of biopharmaceuticals, enzymes, and other biologics through the processing of cell cultures or bio-based products.\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eContact New Life Scientific Today for Additional Information\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAre you ready to discover how the LM10 can help your process achieve desired quality results? Our team can help you decide with your processing needs. \u003c\/span\u003e\u003ca href=\"https:\/\/newlifescientific.com\/pages\/contact-us\"\u003e\u003cspan\u003eContact us\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e today if you have questions or need additional specifications. You may also:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\" dir=\"ltr\"\u003e\u003cspan\u003e\u003cstrong\u003e•\u003c\/strong\u003e Live chat with us by clicking on the icon at the lower right of your screen.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\" dir=\"ltr\"\u003e\u003cspan\u003e\u003cstrong\u003e•\u003c\/strong\u003e Email us at \u003c\/span\u003e\u003ca href=\"mailto:cs@newlifescientific.com\"\u003e\u003cspan\u003ecs@newlifescientific.com\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 40px;\" dir=\"ltr\"\u003e\u003cspan\u003e\u003cstrong\u003e• \u003c\/strong\u003eCall us at \u003c\/span\u003e\u003ca href=\"tel:5672102838\"\u003e\u003cspan\u003e(567)-210-2838\u003c\/span\u003e\u003c\/a\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Microfluidics","offers":[{"title":"Default Title","offer_id":49472247103716,"sku":null,"price":12575.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0064\/4268\/0410\/files\/58690630.jpg?v=1769545948","url":"https:\/\/newlifescientific.com\/products\/ppp-microfluidics-lm10-microfluidizer-high-shear-fluid-processor-homogenizer","provider":"New Life Scientific","version":"1.0","type":"link"}