Overview of VirTis 35L Ultra Freeze Dryer/Lyophilizer with PC & Lyos 2.0
The VirTis 35L Ultra is a pilot-scale freeze dryer efficient for research and also a reliable unit for small-scale production. It reaches shelf temperature as low as -70 degrees Celsius with a large condenser capacity of 35 liters.
View in stock used freeze dryers for sale here. Need assistance? Get in touch with us today.
VirTis 35L Ultra Freeze Dryer Features
Several key features make the Freezemobile FM35EL beneficial for labs needing a compact and customizable instrument:
• Compact design for easy installation
• Single product chamber design allows for larger batches and product uniformity
• Available with a Merlin or LyoS 2.0™ control system
• Optional hydraulic stoppering system available
• Narrow, non cleanroom configuration available
VirTis 35L Ultra Freeze Dryer Specifications
Manufacturer |
SP Scientific |
Model |
35L Ultra EL-85° |
Lowest shelf temperature (50Hz / 60Hz) |
≤ -67°C / -70°C |
Shelf temperature control range |
-55 to 65°C |
Shelf pull-down from 20°C to -40°C |
≤ 40 minutes |
Lowest condenser temperature (50Hz / 60 Hz) |
≤ -82°C / -85°C |
Maximum condenser capacity |
≥ 35 L |
Condenser surface area |
750 in2 (4,838 cm2) |
Condenser pull-down from 20°C to -45°C |
≤ 25 minutes |
Maximum ice condensing capacity in 24 hours |
≥ 20 L |
Maximum deposition rate |
≥ 0.83 L/hour |
Number of compressors |
2 |
Compressor horsepower |
1.5 hp, 1.5 hp |
Vacuum time to 100 mTorr |
≤ 30 minutes |
Vacuum rate of rise |
≤ 30 mT/hour |
Vacuum control +/- 5 mTorr |
50mTorr to 500mTorr |
Volume-based leak rate |
≤ .0036 mbar L/sec |
Lowest system vacuum |
≤ 15 mT |
Temperature uniformity |
± 1.0°C |
Construction |
316L stainless steel shelves, product chamber and condenser chamber |
Stoppering |
Bottom-up hydraulic |
Defrost type |
Hot gas |
Refrigerant type |
CFC-free |
Vapor port |
8 in (20.3 cm) |
Power rating |
208-230VAC, 60Hz, 40A, 1Ph |
Recommended outlet |
NEMA 6-50R |
Overall dimensions (W x D x H) |
50 x 38.75 x 75.75 in |
Minimum clearance |
10 in (25.4 cm) |
Weight |
2,000 lb (909 kg) |
Note: Performance specifications are based on SP test data from units operating at an ambient room temperature of approximately 20°C. SP recommends an optimum operation range of 15-25°C (59-77°F).
Note: SP recommends a 24-inch (61 cm) clearance around all sides of the unit for serviceability. If machines are placed side by side, increase the minimum clearance to 48 inches (121.9 cm)
Our Testing Process
1. Freeze dryer is visually inspected on arrival and then a performance test is initiated to see how well the unit is operating.
2. The interior and exterior of the unit are cleaned using a dry ice blasting method to remove buildup and contaminants.
3. The freeze dryer technician checks the ambient pressures of the high and low side compressors (if applicable). A functional test of the refrigeration circuit is performed to verify that the unit is cooling in accordance with the manufacturer's specifications.
4. Air-cooled units use a condenser and fans to remove heat from the system. The condenser is inspected and cleaned to ensure proper airflow. Water-cooled units use facility water or a standalone chiller to dissipate heat from the refrigeration circuit. The water circuit is inspected for leaks and verified to be functioning correctly.
5. For rotary vane vacuum pumps, the oil is flushed and refilled. Scroll vacuum pumps, which are oil-free, are inspected and calibrated accordingly.
6. For benchtop and floor model freeze dryers equipped with tree and drum manifolds, the valves are cleaned, inspected, and regreased to ensure proper sealing and functionality.
7. The unit’s temperature sensors are calibrated to ensure accurate readings and proper performance (on non-Lyo software units).
8. Door seals and other critical components are inspected and replaced as needed.
9. Refrigeration lines are reinsulated, and all vacuum hoses are inspected or replaced to ensure proper system integrity.
10. If the unit includes software, the technician runs functionality tests, including checking the minimum and maximum achievable temperatures.
11. The freeze dryer technician verifies that the stoppering mechanism (if present) and isolation valves are functioning correctly.
Note: Isolation valves are designed to prevent air leaks within the system and must be tested for proper sealing during operation, heating, and defrost cycles.
12. The unit is repainted and redecaled where necessary to ensure a professional appearance.
NLS' Standard Freezemobile FM35EL Freeze Dryer Accessories
• Product Shelves
• PC with Lyos 2.0 Control Software Installed
• Vacuum Pump
• Corrosive-resistant Glass Door
• Trays
• Vials
• Power Cable
Notice: This freeze dryer is water cooled. You will need to meet this utility requirement to operate this freeze dryer.
Available Freezemobile FM35EL Freeze Dryer Upgrades
• Annual PM Service Visit: Preventative maintenance involves checking vacuum integrity and instrument calibration
• IQ/OQ Service: Installation Qualification and Operational Qualification Service Visit. This can be a requirement for any company that is producing products that fall under FDA Regulations.
• Acid Trap Installation: Necessary for applications that involve the processing of corrosive materials.
Our Freeze Dryer Technician Checklist
At New Life Scientific, our technicians test each device thoroughly before shipping to verify performance and functionality. After our freeze dryer technician finishes the initial testing process, this Freeze Dryer Technician Checklist is filled out to record the important information gathered throughout the repair process. This checklist will be available publicly after the unit has undergone tech completion.
VirTis 35L Ultra Freeze Dryer Applications
• Biopharmaceutical Labs - Labs involved in the production of biologics, including monoclonal antibodies, therapeutic proteins, and peptides, use freeze dryers to stabilize and preserve these sensitive products.
• Vaccine Development Labs - Labs working on vaccine production, especially those requiring lyophilization to preserve the potency of live or inactivated viruses, often rely on freeze-drying.
• Gene and Cell Therapy Labs - Labs focused on gene therapies (e.g., plasmids, mRNA) and cell therapy (e.g., stem cells) use freeze dryers to preserve the viability and stability of biological materials.
• Diagnostic and Assay Labs - Laboratories producing diagnostic kits, reagents, and assays, especially for long-term storage and stability, use freeze dryers to maintain their integrity over time.
• Research and Biotech Labs - Labs involved in biological research, including the preservation of biological samples, cell lines, and microbial cultures, use freeze dryers for sample storage and transportation.
• Blood Bank and Plasma Labs - Labs that process and store blood plasma, serum, and other biological materials often use freeze dryers to maintain the stability of these sensitive components.
• Nutraceutical and Exosome Therapy Labs - Labs producing nutraceuticals (e.g., probiotics) or exosome-based therapies use freeze dryers to stabilize these products for longer shelf life.
Contact New Life Scientific Today for Additional Information
Does the VirTis 35EL Ultra’s capacity and features align with your processing needs? Contact us today if you have questions or need additional specifications. You may also:
• Live chat with us by clicking on the icon at the lower right of your screen.
• Email us at cs@newlifescientific.com
• Call us at (567)-210-2838
Estimate Shipping
VirTis 35L Ultra Freeze Dryer with PC & Lyos 2.0
Overview of VirTis 35L Ultra Freeze Dryer/Lyophilizer with PC & Lyos 2.0
The VirTis 35L Ultra is a pilot-scale freeze dryer efficient for research and also a reliable unit for small-scale production. It reaches shelf temperature as low as -70 degrees Celsius with a large condenser capacity of 35 liters.
View in stock used freeze dryers for sale here. Need assistance? Get in touch with us today.
VirTis 35L Ultra Freeze Dryer Features
Several key features make the Freezemobile FM35EL beneficial for labs needing a compact and customizable instrument:
• Compact design for easy installation
• Single product chamber design allows for larger batches and product uniformity
• Available with a Merlin or LyoS 2.0™ control system
• Optional hydraulic stoppering system available
• Narrow, non cleanroom configuration available
VirTis 35L Ultra Freeze Dryer Specifications
Manufacturer |
SP Scientific |
Model |
35L Ultra EL-85° |
Lowest shelf temperature (50Hz / 60Hz) |
≤ -67°C / -70°C |
Shelf temperature control range |
-55 to 65°C |
Shelf pull-down from 20°C to -40°C |
≤ 40 minutes |
Lowest condenser temperature (50Hz / 60 Hz) |
≤ -82°C / -85°C |
Maximum condenser capacity |
≥ 35 L |
Condenser surface area |
750 in2 (4,838 cm2) |
Condenser pull-down from 20°C to -45°C |
≤ 25 minutes |
Maximum ice condensing capacity in 24 hours |
≥ 20 L |
Maximum deposition rate |
≥ 0.83 L/hour |
Number of compressors |
2 |
Compressor horsepower |
1.5 hp, 1.5 hp |
Vacuum time to 100 mTorr |
≤ 30 minutes |
Vacuum rate of rise |
≤ 30 mT/hour |
Vacuum control +/- 5 mTorr |
50mTorr to 500mTorr |
Volume-based leak rate |
≤ .0036 mbar L/sec |
Lowest system vacuum |
≤ 15 mT |
Temperature uniformity |
± 1.0°C |
Construction |
316L stainless steel shelves, product chamber and condenser chamber |
Stoppering |
Bottom-up hydraulic |
Defrost type |
Hot gas |
Refrigerant type |
CFC-free |
Vapor port |
8 in (20.3 cm) |
Power rating |
208-230VAC, 60Hz, 40A, 1Ph |
Recommended outlet |
NEMA 6-50R |
Overall dimensions (W x D x H) |
50 x 38.75 x 75.75 in |
Minimum clearance |
10 in (25.4 cm) |
Weight |
2,000 lb (909 kg) |
Note: Performance specifications are based on SP test data from units operating at an ambient room temperature of approximately 20°C. SP recommends an optimum operation range of 15-25°C (59-77°F).
Note: SP recommends a 24-inch (61 cm) clearance around all sides of the unit for serviceability. If machines are placed side by side, increase the minimum clearance to 48 inches (121.9 cm)
Our Testing Process
1. Freeze dryer is visually inspected on arrival and then a performance test is initiated to see how well the unit is operating.
2. The interior and exterior of the unit are cleaned using a dry ice blasting method to remove buildup and contaminants.
3. The freeze dryer technician checks the ambient pressures of the high and low side compressors (if applicable). A functional test of the refrigeration circuit is performed to verify that the unit is cooling in accordance with the manufacturer's specifications.
4. Air-cooled units use a condenser and fans to remove heat from the system. The condenser is inspected and cleaned to ensure proper airflow. Water-cooled units use facility water or a standalone chiller to dissipate heat from the refrigeration circuit. The water circuit is inspected for leaks and verified to be functioning correctly.
5. For rotary vane vacuum pumps, the oil is flushed and refilled. Scroll vacuum pumps, which are oil-free, are inspected and calibrated accordingly.
6. For benchtop and floor model freeze dryers equipped with tree and drum manifolds, the valves are cleaned, inspected, and regreased to ensure proper sealing and functionality.
7. The unit’s temperature sensors are calibrated to ensure accurate readings and proper performance (on non-Lyo software units).
8. Door seals and other critical components are inspected and replaced as needed.
9. Refrigeration lines are reinsulated, and all vacuum hoses are inspected or replaced to ensure proper system integrity.
10. If the unit includes software, the technician runs functionality tests, including checking the minimum and maximum achievable temperatures.
11. The freeze dryer technician verifies that the stoppering mechanism (if present) and isolation valves are functioning correctly.
Note: Isolation valves are designed to prevent air leaks within the system and must be tested for proper sealing during operation, heating, and defrost cycles.
12. The unit is repainted and redecaled where necessary to ensure a professional appearance.
NLS' Standard Freezemobile FM35EL Freeze Dryer Accessories
• Product Shelves
• PC with Lyos 2.0 Control Software Installed
• Vacuum Pump
• Corrosive-resistant Glass Door
• Trays
• Vials
• Power Cable
Notice: This freeze dryer is water cooled. You will need to meet this utility requirement to operate this freeze dryer.
Available Freezemobile FM35EL Freeze Dryer Upgrades
• Annual PM Service Visit: Preventative maintenance involves checking vacuum integrity and instrument calibration
• IQ/OQ Service: Installation Qualification and Operational Qualification Service Visit. This can be a requirement for any company that is producing products that fall under FDA Regulations.
• Acid Trap Installation: Necessary for applications that involve the processing of corrosive materials.
Our Freeze Dryer Technician Checklist
At New Life Scientific, our technicians test each device thoroughly before shipping to verify performance and functionality. After our freeze dryer technician finishes the initial testing process, this Freeze Dryer Technician Checklist is filled out to record the important information gathered throughout the repair process. This checklist will be available publicly after the unit has undergone tech completion.
VirTis 35L Ultra Freeze Dryer Applications
• Biopharmaceutical Labs - Labs involved in the production of biologics, including monoclonal antibodies, therapeutic proteins, and peptides, use freeze dryers to stabilize and preserve these sensitive products.
• Vaccine Development Labs - Labs working on vaccine production, especially those requiring lyophilization to preserve the potency of live or inactivated viruses, often rely on freeze-drying.
• Gene and Cell Therapy Labs - Labs focused on gene therapies (e.g., plasmids, mRNA) and cell therapy (e.g., stem cells) use freeze dryers to preserve the viability and stability of biological materials.
• Diagnostic and Assay Labs - Laboratories producing diagnostic kits, reagents, and assays, especially for long-term storage and stability, use freeze dryers to maintain their integrity over time.
• Research and Biotech Labs - Labs involved in biological research, including the preservation of biological samples, cell lines, and microbial cultures, use freeze dryers for sample storage and transportation.
• Blood Bank and Plasma Labs - Labs that process and store blood plasma, serum, and other biological materials often use freeze dryers to maintain the stability of these sensitive components.
• Nutraceutical and Exosome Therapy Labs - Labs producing nutraceuticals (e.g., probiotics) or exosome-based therapies use freeze dryers to stabilize these products for longer shelf life.
Contact New Life Scientific Today for Additional Information
Does the VirTis 35EL Ultra’s capacity and features align with your processing needs? Contact us today if you have questions or need additional specifications. You may also:
• Live chat with us by clicking on the icon at the lower right of your screen.
• Email us at cs@newlifescientific.com
• Call us at (567)-210-2838
Related Products


Freeze Dryer, Floor, Shelf Style
SP VirTis 35L Ultra EL-85°C Stoppering Freeze Dryer with PC and Lyos 2.0
Item No. 27014
• Condenser Temp. -85°C
• Mfg. Date 2021
• With LyoS 2.0 Control Software


Freeze Dryer, Floor, Shelf Style
SP VirTis Ultra 35 EL-85°C Stoppering Freeze Dryer Lyophilizer w/ PC and Maestro
Item No. 25761
• Condenser Temp. -85°C
• Mfg. Date 2003
• With Maestro Control Software
Payment & Security
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
READY TO BUY OR SELL USED LAB EQUIPMENT?
We can help. In addition to selling lab equipment, we also purchase it.