BIAcore 2000 Automated Surface Plasmon Resonance Biosensor System in Good Condition
This BIAcore 2000 SPR system has been tested to successfully power on and initialize by our technical staff. When powered on, all five status LEDs illuminate, then both the "Ready" and "Sensor Chip" LEDs remains lit green. Additionally, the "Temperature" LED flashes amber to indicate that the heater is warming.
Included with this SPR system are a maintenance sensor card, power cable, and 90-day warranty.
Aside from some wear on the body and a scuff on the label, this BIAcore 2000 is in good condition and bears no damage. The interior is very clean with spillage or staining. Please review the photos to see more of the cosmetic condition.
- Biacore 2000 Automated SPR Biosensor System
- Maintenance Sensor Card
- Power Cable
New Life Scientific is an experienced scientific vendor with a history of positive customer experiences. You can have confidence in our technical evaluations and our warranty knowing that we have actual in-house technicians who inspect, test, service, and repair the various instruments we receive.
After examination and thorough cleaning, products often leave our shop meeting manufacturer specs. When you buy from New Life Scientific, you’re free to contact us at any time for after-sales support concerning any questions or issues that may arise, even after your warranty expires.
Manufacturer
|
BIAcore
|
Model
|
BIAcore 2000
|
Code No.
|
BR-1002-25
|
Serial No.
|
33-6689-2125
|
Concentration Measurement
|
Four analysis times <15 minutes, precision ≤5% CV dose
|
High molecular weight analytes (10^4 - 10^6 g/mole)
|
Direct assay: typically 10^-5 - 10^-9 M Sandwich assay: typically 10^-3 - 10^-11 M
|
Low molecule weight analytes (<5000 g/mole)
|
Inhibition assay: typically 10^-3 - 19^-9 M
|
Detection Unit
|
Light Source: LED Wavelength: 760 nm Band Width: <5 nm Temperature Range: 4 - 40°C (not lower than 20°C below ambient temperature) Temperature Equilibration Time:
- after 5°C step: typically <60 minutes
- after 10°C step: typically <120 minutes
|
Pump
|
Flow rate range: 1-5000ul/min (1-100 ul/min user-controlled) Increments: Steps of 1ul/min Flow rate accuracy: Flow rate precision: <1% (1-100ul/min, liquid at 25°C) Pressure range: <0.2 MPa
|
Autosampler
|
Dispensing volume range: 5 - 500ul (including air segment) Increments: Steps of 1 ul/min Accuracy: <1% deviation for volumes >= 50ul Precision:
- 50ul: <0.4% CV
- 5ul: <2% CV
|
Autosampler capacity per rack
|
Microtitre plate: 96 (0.2 ml/well) Rack Type A:
- 5 vials, diam. 16mm (4 ml)
- 12 vials, diam. 9 mm (1.5 ml)
- 40 vials, diam. 7 mm (0.7 ml)
Rack Type B: 60 vials, diam. 9 mm (1.5ml) Rack Type C: 24 vials, diam. 10.8 mm (Eppendorf-type 1.5-2ml)
|
Dimensions (W x D x H)
|
30" x 14.5" x 24"
|
Power Specifications
|
100-120V/220-240V, 47-63Hz, 580VA Max
|
Backed by a 90-Day Warranty - Your instrument works, or we repair, refund, or replace.
Used - A pre-owned and tested product that may show signs of wear.
U.S. & Canada Freight ($285) - Exclusive shipping to the U.S. and Canada. Freighted products below $1,500 are assigned this profile.