Becton Dickinson FACSCalibur Flow Cytometer w Cytek DxP Multi-Color

Warranty

  • Includes a 90-Day warranty
  • 1-Year Warranty Upgrade Available. Contact for pricing

QUALITY ASSURED BY NLS TECH STAFF

Price:
Sale price$2,995.00
Specs Below
click to see what's included

You Will Receive
     - Becton Dickinson FACSCalibur Flow Cytometer
     - Cytek DxP Multi-Color
     - PC keyboard 
     - Mouse
     - Power cable

Note: This does not include a monitor but it can be used with any Standard VGA monitor. 


Why is this being sold “For-Parts or Repair”?

     We were not able to get the PC to acknowledge it when it was connected. We used a USB to serial adapter with only one serial port but lack knowledge of how the connection is to be configured. There is a good chance that this can be brought back into working condition by someone with a little experience with the FACSCaliber/Cytek system and software.


Specifications 

Cytometer Specifications

Manufacturer

Becton Dickinson

Model

FACSCalibur

Serial No.

1272

Mfg. Date

2003

Dimensions (W x D x H)

Sensor Module

36 in x 24.2 in x 26.5 in / 49 in with cover open


Computer: 48 x 41 x 54 cm (19”L x 16”D x 23”H)

Weight

Sensor Module: 109.1 kg (240 lbs) Computer: 50 kg (110 lbs)

Fluidics

General Operation

Front key panel control provides three modes: RUN, STNDBY, and PRIME; automatic standby mode conserves sheath fluid by stopping sheath flow when no sample tube is installed.

Fluid Reservoirs

Easily accessible 4-L capacity sheath and waste containers are housed in a convenient pull-out drawer; level detectors automatically indicate low levels of sheath or high levels of waste.

Sample Flow Rates

Three selectable flow rates of 60 µL/min, 35 µL/min, and 12 µL/min. Pressure difference between sheath and sample is regulated and monitored; particle velocity in flow cell is approximately 6 meters/second.

Quartz Cuvette

Internal cross-section is rectangular 430 µm x 180 µm; external surfaces are anti-reflection coated for maximum transmission of laser light

Sample Concentration

Single-cell suspension of 105 to 2 x 107 particles/mL recommended range

Signal Processing

Workstation Resolution

1024 channels on all parameters

Dynamic range

Logarithmic amplifiers for SSC, FL1, FL2, FL3, and FL4 (with FL4 option) provide four log decade range

Fluorescence Compensation Networks

Fluorescence spectral overlap can be compensated between FL1 and FL2, between FL2 and FL3 channels, and between FL3 and FL4 (with FL4 option)

Pulse Processing

Width and Area measurements for discriminating doublets; available for all fluorescence parameters

Time

Time available correlated to any parameter for kinetic experiments or other applications.


Sample Loading Specifications

Sample delivery

Tube-lifter design with multiple sensors which verify rack identification and tube position

Rack Capacity

40 (12 x 75-mm) tubes per rack

Rack Support

Up to 16 racks per FACS Loader 

Data Entry

Sample information, reagent panels, and rack information can be defined for up to 640 tubes (40 tubes x 16 racks) at a time

Loader Control

Automated control through WorklistManager software and manual control with stat interrupt capability through FACS Loader electronic keypad

Mixing Mode

Adjustable High Energy and Low Energy mix


Sorting Specifications

Sorting Purity

>95%

Capture Rate

300 cells/second

Sort Modes

Three modes (all aerosol-free): single cell, exclusion, and recovery

Recovery

Depends upon sample and sorting conditions, >50%

Sterile Sorting

System design allows for aerosol-free sterile sorting

Estimate Shipping

Becton Dickinson FACSCalibur Flow Cytometer w Cytek DxP Multi-Color

You Will Receive
     - Becton Dickinson FACSCalibur Flow Cytometer
     - Cytek DxP Multi-Color
     - PC keyboard 
     - Mouse
     - Power cable

Note: This does not include a monitor but it can be used with any Standard VGA monitor. 


Why is this being sold “For-Parts or Repair”?

     We were not able to get the PC to acknowledge it when it was connected. We used a USB to serial adapter with only one serial port but lack knowledge of how the connection is to be configured. There is a good chance that this can be brought back into working condition by someone with a little experience with the FACSCaliber/Cytek system and software.


Specifications 

Cytometer Specifications

Manufacturer

Becton Dickinson

Model

FACSCalibur

Serial No.

1272

Mfg. Date

2003

Dimensions (W x D x H)

Sensor Module

36 in x 24.2 in x 26.5 in / 49 in with cover open


Computer: 48 x 41 x 54 cm (19”L x 16”D x 23”H)

Weight

Sensor Module: 109.1 kg (240 lbs) Computer: 50 kg (110 lbs)

Fluidics

General Operation

Front key panel control provides three modes: RUN, STNDBY, and PRIME; automatic standby mode conserves sheath fluid by stopping sheath flow when no sample tube is installed.

Fluid Reservoirs

Easily accessible 4-L capacity sheath and waste containers are housed in a convenient pull-out drawer; level detectors automatically indicate low levels of sheath or high levels of waste.

Sample Flow Rates

Three selectable flow rates of 60 µL/min, 35 µL/min, and 12 µL/min. Pressure difference between sheath and sample is regulated and monitored; particle velocity in flow cell is approximately 6 meters/second.

Quartz Cuvette

Internal cross-section is rectangular 430 µm x 180 µm; external surfaces are anti-reflection coated for maximum transmission of laser light

Sample Concentration

Single-cell suspension of 105 to 2 x 107 particles/mL recommended range

Signal Processing

Workstation Resolution

1024 channels on all parameters

Dynamic range

Logarithmic amplifiers for SSC, FL1, FL2, FL3, and FL4 (with FL4 option) provide four log decade range

Fluorescence Compensation Networks

Fluorescence spectral overlap can be compensated between FL1 and FL2, between FL2 and FL3 channels, and between FL3 and FL4 (with FL4 option)

Pulse Processing

Width and Area measurements for discriminating doublets; available for all fluorescence parameters

Time

Time available correlated to any parameter for kinetic experiments or other applications.


Sample Loading Specifications

Sample delivery

Tube-lifter design with multiple sensors which verify rack identification and tube position

Rack Capacity

40 (12 x 75-mm) tubes per rack

Rack Support

Up to 16 racks per FACS Loader 

Data Entry

Sample information, reagent panels, and rack information can be defined for up to 640 tubes (40 tubes x 16 racks) at a time

Loader Control

Automated control through WorklistManager software and manual control with stat interrupt capability through FACS Loader electronic keypad

Mixing Mode

Adjustable High Energy and Low Energy mix


Sorting Specifications

Sorting Purity

>95%

Capture Rate

300 cells/second

Sort Modes

Three modes (all aerosol-free): single cell, exclusion, and recovery

Recovery

Depends upon sample and sorting conditions, >50%

Sterile Sorting

System design allows for aerosol-free sterile sorting

Payment & Security
  • American Express
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

READY TO BUY OR SELL USED LAB EQUIPMENT?

We can help. In addition to selling lab equipment, we also purchase it.

Contact us below for immediate service.

Ask a Question or Request a quote!