You Will Receive
- Becton Dickinson FACSCalibur Flow Cytometer
- Cytek DxP Multi-Color
- PC keyboard
- Mouse
- Power cable
Note: This does not include a monitor but it can be used with any Standard VGA monitor.
Why is this being sold “For-Parts or Repair”?
We were not able to get the PC to acknowledge it when it was connected. We used a USB to serial adapter with only one serial port but lack knowledge of how the connection is to be configured. There is a good chance that this can be brought back into working condition by someone with a little experience with the FACSCaliber/Cytek system and software.
Specifications
Cytometer Specifications
Manufacturer
|
Becton Dickinson
|
Model
|
FACSCalibur
|
Serial No.
|
1272
|
Mfg. Date
|
2003
|
Dimensions (W x D x H)
|
Sensor Module
36 in x 24.2 in x 26.5 in / 49 in with cover open
Computer: 48 x 41 x 54 cm (19”L x 16”D x 23”H)
|
Weight
|
Sensor Module: 109.1 kg (240 lbs) Computer: 50 kg (110 lbs)
|
Fluidics
|
General Operation
|
Front key panel control provides three modes: RUN, STNDBY, and PRIME; automatic standby mode conserves sheath fluid by stopping sheath flow when no sample tube is installed.
|
Fluid Reservoirs
|
Easily accessible 4-L capacity sheath and waste containers are housed in a convenient pull-out drawer; level detectors automatically indicate low levels of sheath or high levels of waste.
|
Sample Flow Rates
|
Three selectable flow rates of 60 µL/min, 35 µL/min, and 12 µL/min. Pressure difference between sheath and sample is regulated and monitored; particle velocity in flow cell is approximately 6 meters/second.
|
Quartz Cuvette
|
Internal cross-section is rectangular 430 µm x 180 µm; external surfaces are anti-reflection coated for maximum transmission of laser light
|
Sample Concentration
|
Single-cell suspension of 105 to 2 x 107 particles/mL recommended range
|
Signal Processing
|
Workstation Resolution
|
1024 channels on all parameters
|
Dynamic range
|
Logarithmic amplifiers for SSC, FL1, FL2, FL3, and FL4 (with FL4 option) provide four log decade range
|
Fluorescence Compensation Networks
|
Fluorescence spectral overlap can be compensated between FL1 and FL2, between FL2 and FL3 channels, and between FL3 and FL4 (with FL4 option)
|
Pulse Processing
|
Width and Area measurements for discriminating doublets; available for all fluorescence parameters
|
Time
|
Time available correlated to any parameter for kinetic experiments or other applications.
|
Sample Loading Specifications
Sample delivery
|
Tube-lifter design with multiple sensors which verify rack identification and tube position
|
Rack Capacity
|
40 (12 x 75-mm) tubes per rack
|
Rack Support
|
Up to 16 racks per FACS Loader
|
Data Entry
|
Sample information, reagent panels, and rack information can be defined for up to 640 tubes (40 tubes x 16 racks) at a time
|
Loader Control
|
Automated control through WorklistManager software and manual control with stat interrupt capability through FACS Loader electronic keypad
|
Mixing Mode
|
Adjustable High Energy and Low Energy mix
|
Sorting Specifications
Sorting Purity
|
>95%
|
Capture Rate
|
300 cells/second
|
Sort Modes
|
Three modes (all aerosol-free): single cell, exclusion, and recovery
|
Recovery
|
Depends upon sample and sorting conditions, >50%
|
Sterile Sorting
|
System design allows for aerosol-free sterile sorting
|