Overview of Beckman Coulter Allegra X-30 Benchtop Centrifuge

The Beckman Coulter Allegra X-30 is a general purpose, benchtop centrifuge that performs with endurance under the most exacting standards. The X-30 Series offers 13 different rotors and multiple pre-bundled application packages, accommodating cell culture processing, blood sample preparation, and microplate application. Its streamlined user interface makes operation a breeze.And with increased capacity, you can run more samples simultaneously.

View in stock used benchtop centrifuge for sale here. Need assistance? Get in touch with us today.



Beckman Coulter Allegra X-30 Benchtop Centrifuge Features

Here are the key features of a Beckman Coulter Allegra X-30:

•  Capacity: The Allegra X-30 can handle up to 1.6 Liters (4 x 400 mL) of volume at 16,000 rpm speed and 23,511 x g relative centrifugal force (RCF) with a fixed-angle rotor while at 3,398 rpm speed and 4,200 x g RCF with a swing-bucket rotor.

•  User-friendly: The Allegra X-30’s control panel is mounted at an angle on the front of the centrifuge and includes system keys, programming keys, and digital displays. The panel also contains an “IMBALANCE” light that flashes if rotor loads are severely out of balance.

•  Safety: The Allegra X-30’s door has an electromechanical door-locking mechanism to prevent operator contact with spinning rotors. An overspeed system continuously monitors the rotor during centrifugation. It is also equipped with an imbalance detector that monitors the rotor during the run, causing automatic shutdown if rotor loads are severely out of balance. The centrifuge feet, made of rubber, have been designed to minimize possible rotation in the event of a rotor mishap.


Beckman Coulter Allegra X-30 Specifications

Manufacturer

Beckman Coulter

Model

Allegra X-30

Max Speed

3,398 rpm (swing bucket)
16,000 rpm (fixed angle)

Max g-Force

4,200 x g (swing bucket)
23,511 x g (fixed angle)

Acceleration

10 acceleration profiles

Deceleration

10 deceleration profiles

Run Time

`Up to 9 hrs, 59 mins: Continuous run (8)

Refrigeration

No

Drive Type Cooling

Brushless induction

Temperature Range

Ambient temperature range +4ºC to +35ºC

Friction Reduction System

Asynchronous 3-phase direct drive

Installation Category

II

Weight

105.8 lbs (48 kg)

Electrical Requirements

120V, 60Hz, 6A

Dimensions (WxDxH)

18 x 22 x 14 in.





Our Testing Process

1. Centrifuge technician pre-tests the unit’s (1) speed sometimes to maximum speed for a few minutes, (2) refrigeration (if equipped), (3) spinning if they spin up and spin down properly, (4) checks the buttons, switches, timers if they are all working. Necessary parts for repair are ordered.

2. Once any parts come in for the unit, or they’re working, the centrifuge technician performs any necessary repairs.

3. The centrifuge technician runs the unit to maximum RPMs for a minimum of 1 hour while observing the refrigeration performance (if applicable). During this step, loud/unusual noises, smells, and extra heat build up are observed.

4. The centrifuge technician also observes the proper performance of sensors like temperature, vacuum (if equipped), rotor sensors, tach sensors, latch sensors, etc.

5. After a full hour run, the centrifuge technician takes a photo of the centrifuge display to be shown in the listing photos on New Life Scientific’s e-commerce platforms.

6. The centrifuge technician then does a thorough look over throughout the centrifuge to identify anything that is missing, loose, or damaged. The centrifuge technician follows New Life Scientific’s Centrifuge Technician Checklist at this time to make sure everything is checked accordingly.

7. The refrigeration condenser and chassis cleaned are both handled by blowing out the unit with compressed air or dry ice blasting.

8. Sensors are cleaned and/or re-installed with proper gap. Electrical connections are latched and tightened down properly.

9. Drive mounts, drive brushes, gas springs are checked and replaced, if necessary.

10. The centrifuge is then cleaned and if needed, painted as well, to make sure the unit comes out as standard as we can.


 

NLS' Standard Allegra X-30 Centrifuge Upgrades and Accessories

•  Rotor
•  Rotor buckets
  Rotor buckets adapters
  Power cable
  90-Day to 1-Year Warranty

 

Our Centrifuge Technician Checklist

At New Life Scientific, our technicians test each device thoroughly before shipping to verify performance and functionality. After our centrifuge technician finishes the initial testing process, this Centrifuge Technician Checklist is filled out to record the important information gathered throughout the repair process. This checklist will be available publicly after the unit has undergone tech completion. 

 

Beckman Coulter Allegra X-30 Benchtop Centrifuge Applications

Cell Biology and Biochemistry - The centrifuge is commonly used for harvesting cells from cultures in bioprocessing, cell culture studies, and in research applications. It aids in separating proteins from other cellular components in studies related to biochemistry. It also helps isolate and concentrate RNA or DNA from biological samples.

Blood Separation - Centrifuges are used to separate blood components (plasma, serum, and cells) for diagnostic tests, blood banking, or plasma collection for medical treatments.

Urine and Stool Sample Analysis - For isolating cells, bacteria, or other particles for microbiological analysis or diagnostics.

Microbiological Testing - Separation of microorganisms from biological samples for culture or identification.

Water Quality Testing - Used to separate particulates, microorganisms, or contaminants from water samples for analysis in environmental monitoring.

Viral Particle Isolation - In research on viruses, benchtop centrifuges help isolate viral particles from cell cultures or biological samples.

Gene Therapy Applications - In genetic research, centrifuges assist in separating viral vectors, plasmids, or other generic materials from cultures.

Nanoparticle Synthesis - Used for separating nanoparticles or other fine materials form solution after synthesis.

Food and Beverage Industry - Used to separate fats from milk or cream during processing in the dairy industry. Used to remove pulp and other solid particles from fruit juice. In the fermentation process for beer and wine production, centrifuges help separate yeast from liquids.

Forensic Science - In forensic investigations, benchtop centrifuges help isolate blood components or bodily fluids for DNA extraction and analysis. Can also help to analyze drugs, poisons, or other toxic compounds.

Teaching Tool/Educational - In educational settings, benchtop centrifuges are used in laboratory classes for demonstrations on centrifugation principles and sample preparation techniques.


 

Contact New Life Scientific Today for Additional Information

Our team can help you decide whether the Allegra X-30’s capacity and features align with your processing needs. Contact us today if you have questions or need additional specifications. You may also:

Live chat with us by clicking on the icon at the lower right of your screen.

Email us at cs@newlifescientific.com

Call us at (567)-210-2838

 

Estimate Shipping

Beckman Coulter Allegra X-30 Benchtop Centrifuge

Payment & Security
  • American Express
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

READY TO BUY OR SELL USED LAB EQUIPMENT?

We can help. In addition to selling lab equipment, we also purchase it.

Contact us below for immediate service.

Ask a Question or Request a quote!