View in stock floor centrifuges here.
Our Centrifuge Testing Process
1. Centrifuge technician pre-tests the unit’s (1) speed sometimes to maximum speed for a few minutes, (2) refrigeration (if equipped), (3) spinning if they spin up and spin down properly, (4) checks the buttons, switches, timers if they are all working. Necessary parts for repair are ordered.
2. Once any parts come in for the unit, or they’re working, the centrifuge technician performs any necessary repairs.
3. The centrifuge technician runs the unit to maximum RPMs for a minimum of 1 hour while observing the refrigeration performance (if applicable). During this step, loud/unusual noises, smells, and extra heat build up are observed.
4. The centrifuge technician also observes the proper performance of sensors like temperature, vacuum (if equipped), rotor sensors, tach sensors, latch sensors, etc.
5. After a full hour run, the centrifuge technician takes a photo of the centrifuge display to be shown in the listing photos on New Life Scientific’s e-commerce platforms.
6. The centrifuge technician then does a thorough look over throughout the centrifuge to identify anything that is missing, loose, or damaged. The centrifuge technician follows New Life Scientific’s Centrifuge Technician Checklist at this time to make sure everything is checked accordingly.
7. The refrigeration condenser and chassis cleaned are both handled by blowing out the unit with compressed air or dry ice blasting.
8. Sensors are cleaned and/or re-installed with proper gap. Electrical connections are latched and tightened down properly ensuring they have proper power cable.
9. Drive mounts, drive brushes, gas springs are checked and replaced, if necessary.
10. The centrifuge is then cleaned and if needed, painted as well, to make sure the unit comes out as standard as we can.
Sorvall Lynx Upgrades and Accessories
- Rotor
- Buckets
- Bucket Adapters
- Maintenance Kit
- Power cable
- 90-Day to 1-Year Warranty
Our Centrifuge Technician Checklist
After our centrifuge technician finishes the initial testing process, this Centrifuge Technician Checklist is filled out to record the important information gathered throughout the repair process. This checklist will be available publicly after the unit has undergone tech completion and is ready for the customers.
Floor Centrifuge Applications
- Cell Biology and Biochemistry - The centrifuge is commonly used for harvesting cells from cultures in bioprocessing, cell culture studies, and in research applications. It aids in separating proteins from other cellular components in studies related to biochemistry. It also helps isolate and concentrate RNA or DNA from biological samples.
- Molecular Biology - Used for separating nucleic acids (DNA/RNA) from crude samples or for concentrating nucleic acid solutions. It is useful in isolating plasmid DNA from bacterial cultures.
- Clinical and Diagnostic Applications - The Sorvall Lynx Centrifuge is used in clinical labs to process blood samples, separate plasma, serum, and blood cells for diagnostic testing.
- Microbiological Studies - In industrial microbiology, it is applied for the recovery of microbial biomass from fermentation media.
- Environmental Sciences - Used for separating suspended solids in water and soil samples. It aids in processing samples for monitoring environmental contaminants.
- Pharmaceutical, Biotechnology, and Research Applications - The Sorvall Lynx centrifuge is used in the production and purification of biologics, such as vaccines and monoclonal antibodies. It is also applied in the preparation of viral vectors used for gene therapy. It is widely used for clarifying complex biological samples in academic and industrial research settings.
Sorvall Lynx 6000/4000 Specifications
Model |
Sorvall Lynx 4000 |
Sorvall Lynx 6000 |
Manufacturer |
||
Type |
||
Capacity |
4 x 1000 mL |
6 x 1000 mL |
Max. speed |
24,000 rpm |
29,000 rpm |
Max. RCF |
68,905 x g |
100,605 x g |
Refrigerated |
Yes |
Yes |
Accel/decel profiles |
9 Accel, 10 Decel |
9 Accel, 10 Decel |
Controller type |
Touchscreen interface |
Touchscreen interface |
Temperature range |
-10° to +40°C |
-20°C to +40°C |
Drive system |
High torque brushless |
High torque brushless |
Noise level |
<59 dBA |
<59 dBA |
Power rating |
200-240V, 50/60Hz, 30A, 1Ph |
200/240V, 50/60Hz, 30A, 1Ph |
Dimensions (W x D x H) |
27.6 x 31.7 x 41 in |
27.6 x 31.7 x 36.6 in |
Weight |
622 lb (283 kg) |
644 lb (293 kg) |
Need Assistance? We're Happy to Help!
- Live chat with us by clicking on the icon at the lower right of your screen.
- Email us at cs@newlifescientific.com
- Call us at (567)-210-2838
Estimate Shipping
Thermo Scientific Sorvall Lynx 6000/4000 Floor Centrifuge
View in stock floor centrifuges here.
Our Centrifuge Testing Process
1. Centrifuge technician pre-tests the unit’s (1) speed sometimes to maximum speed for a few minutes, (2) refrigeration (if equipped), (3) spinning if they spin up and spin down properly, (4) checks the buttons, switches, timers if they are all working. Necessary parts for repair are ordered.
2. Once any parts come in for the unit, or they’re working, the centrifuge technician performs any necessary repairs.
3. The centrifuge technician runs the unit to maximum RPMs for a minimum of 1 hour while observing the refrigeration performance (if applicable). During this step, loud/unusual noises, smells, and extra heat build up are observed.
4. The centrifuge technician also observes the proper performance of sensors like temperature, vacuum (if equipped), rotor sensors, tach sensors, latch sensors, etc.
5. After a full hour run, the centrifuge technician takes a photo of the centrifuge display to be shown in the listing photos on New Life Scientific’s e-commerce platforms.
6. The centrifuge technician then does a thorough look over throughout the centrifuge to identify anything that is missing, loose, or damaged. The centrifuge technician follows New Life Scientific’s Centrifuge Technician Checklist at this time to make sure everything is checked accordingly.
7. The refrigeration condenser and chassis cleaned are both handled by blowing out the unit with compressed air or dry ice blasting.
8. Sensors are cleaned and/or re-installed with proper gap. Electrical connections are latched and tightened down properly ensuring they have proper power cable.
9. Drive mounts, drive brushes, gas springs are checked and replaced, if necessary.
10. The centrifuge is then cleaned and if needed, painted as well, to make sure the unit comes out as standard as we can.
Sorvall Lynx Upgrades and Accessories
- Rotor
- Buckets
- Bucket Adapters
- Maintenance Kit
- Power cable
- 90-Day to 1-Year Warranty
Our Centrifuge Technician Checklist
After our centrifuge technician finishes the initial testing process, this Centrifuge Technician Checklist is filled out to record the important information gathered throughout the repair process. This checklist will be available publicly after the unit has undergone tech completion and is ready for the customers.
Floor Centrifuge Applications
- Cell Biology and Biochemistry - The centrifuge is commonly used for harvesting cells from cultures in bioprocessing, cell culture studies, and in research applications. It aids in separating proteins from other cellular components in studies related to biochemistry. It also helps isolate and concentrate RNA or DNA from biological samples.
- Molecular Biology - Used for separating nucleic acids (DNA/RNA) from crude samples or for concentrating nucleic acid solutions. It is useful in isolating plasmid DNA from bacterial cultures.
- Clinical and Diagnostic Applications - The Sorvall Lynx Centrifuge is used in clinical labs to process blood samples, separate plasma, serum, and blood cells for diagnostic testing.
- Microbiological Studies - In industrial microbiology, it is applied for the recovery of microbial biomass from fermentation media.
- Environmental Sciences - Used for separating suspended solids in water and soil samples. It aids in processing samples for monitoring environmental contaminants.
- Pharmaceutical, Biotechnology, and Research Applications - The Sorvall Lynx centrifuge is used in the production and purification of biologics, such as vaccines and monoclonal antibodies. It is also applied in the preparation of viral vectors used for gene therapy. It is widely used for clarifying complex biological samples in academic and industrial research settings.
Sorvall Lynx 6000/4000 Specifications
Model |
Sorvall Lynx 4000 |
Sorvall Lynx 6000 |
Manufacturer |
||
Type |
||
Capacity |
4 x 1000 mL |
6 x 1000 mL |
Max. speed |
24,000 rpm |
29,000 rpm |
Max. RCF |
68,905 x g |
100,605 x g |
Refrigerated |
Yes |
Yes |
Accel/decel profiles |
9 Accel, 10 Decel |
9 Accel, 10 Decel |
Controller type |
Touchscreen interface |
Touchscreen interface |
Temperature range |
-10° to +40°C |
-20°C to +40°C |
Drive system |
High torque brushless |
High torque brushless |
Noise level |
<59 dBA |
<59 dBA |
Power rating |
200-240V, 50/60Hz, 30A, 1Ph |
200/240V, 50/60Hz, 30A, 1Ph |
Dimensions (W x D x H) |
27.6 x 31.7 x 41 in |
27.6 x 31.7 x 36.6 in |
Weight |
622 lb (283 kg) |
644 lb (293 kg) |
Need Assistance? We're Happy to Help!
- Live chat with us by clicking on the icon at the lower right of your screen.
- Email us at cs@newlifescientific.com
- Call us at (567)-210-2838
Related Products


Centrifuge, Floor, Standard High-Speed
Thermo Scientific Sorvall Lynx 4000 Floor Centrifuge


Centrifuge, Floor, Standard High-Speed
Thermo Scientific Sorvall Lynx 6000/4000 Floor Centrifuge


Centrifuge, Floor, Standard High-Speed
Thermo Sorvall Lynx 6000 Refrigerated Floor Centrifuge and F9-6x1000 LEX Rotor


Centrifuge, Floor, Standard High-Speed
Thermo Sorvall Lynx 6000 Refrigerated Floor Centrifuge with F9-6x1000 LEX Rotor
Payment & Security
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
READY TO BUY OR SELL USED LAB EQUIPMENT?
We can help. In addition to selling lab equipment, we also purchase it.
Contact us below for immediate service.