Labconco FreeZone Triad Stoppering Tray Freeze Dryer/Lyophilizer

Warranty

  • Includes a 90-Day warranty
  • 1-Year Warranty Upgrade Available. Contact for pricing

QUALITY ASSURED BY NLS TECH STAFF

Specs Below
click to see what's included

View in stock used freeze dryers for sale here.

 

Our Testing Process

1. Freeze dryer is visually inspected on arrival and then a performance test is initiated to see how well the unit is operating.

2. The interior and exterior of the unit are cleaned using a dry ice blasting method to remove buildup and contaminants.

3. The freeze dryer technician checks the ambient pressures of the high and low side compressors (if applicable). A functional test of the refrigeration circuit is performed to verify that the unit is cooling in accordance with the manufacturer's specifications.

4. Air-cooled units use a condenser and fans to remove heat from the system. The condenser is inspected and cleaned to ensure proper airflow. Water-cooled units use facility water or a standalone chiller to dissipate heat from the refrigeration circuit. The water circuit is inspected for leaks and verified to be functioning correctly.

5. For rotary vane vacuum pumps, the oil is flushed and refilled. Scroll vacuum pumps, which are oil-free, are inspected and calibrated accordingly.

6. For benchtop and floor model freeze dryers equipped with tree and drum manifolds, the valves are cleaned, inspected, and regreased to ensure proper sealing and functionality.

7. The unit’s temperature sensors are calibrated to ensure accurate readings and proper performance (on non-Lyo software units).

8. Door seals and other critical components are inspected and replaced as needed.

9. Refrigeration lines are reinsulated, and all vacuum hoses are inspected or replaced to ensure proper system integrity.

10. If the unit includes software, the technician runs functionality tests, including checking the minimum and maximum achievable temperatures.

11. The freeze dryer technician verifies that the stoppering mechanism (if present) and isolation valves are functioning correctly.

Note: Isolation valves are designed to prevent air leaks within the system and must be tested for proper sealing during operation, heating, and defrost cycles.

12. The unit is repainted and redecaled where necessary to ensure a professional appearance.

 

Upgrades and Accessories

- Manifold with valves
- Vacuum Pump
- Vacuum Hose
- 90-Day to 1-Year Warranty

 

Our Freeze Dryer Technician Checklist

After our freeze dryer technician finishes the initial testing process, this Freeze Dryer Technician Checklist is filled out to record the important information gathered throughout the repair process. This checklist will be available publicly after the unit has undergone tech completion and is ready for the customers. 

 

Labconco FreeZone Triad Freeze Dryer Applications

  • Biopharmaceutical Labs - Labs involved in the production of biologics, including monoclonal antibodies, therapeutic proteins, and peptides, use freeze dryers to stabilize and preserve these sensitive products.
  • Vaccine Development Labs - Labs working on vaccine production, especially those requiring lyophilization to preserve the potency of live or inactivated viruses, often rely on freeze-drying.
  • Gene and Cell Therapy Labs - Labs focused on gene therapies (e.g., plasmids, mRNA) and cell therapy (e.g., stem cells) use freeze dryers to preserve the viability and stability of biological materials.
  • Diagnostic and Assay Labs - Laboratories producing diagnostic kits, reagents, and assays, especially for long-term storage and stability, use freeze dryers to maintain their integrity over time.
  • Research and Biotech Labs - Labs involved in biological research, including the preservation of biological samples, cell lines, and microbial cultures, use freeze dryers for sample storage and transportation.
  • Blood Bank and Plasma Labs - Labs that process and store blood plasma, serum, and other biological materials often use freeze dryers to maintain the stability of these sensitive components.
  • Nutraceutical and Exosome Therapy Labs - Labs producing nutraceuticals (e.g., probiotics) or exosome-based therapies use freeze dryers to stabilize these products for longer shelf life.

 


 

FreeZone Triad Specifications

Manufacturer

Labconco

Model

FreeZone Triad

Collector minimum temperature

-85°C (-121°F)

Collector capacity in 24 Hours

1.84 L

Collector total capacity

2.5 L

Shelf minimum temperature

-75°C

Shelf control temperature range

-55°C to +50°C

Number of shelves

1

Defrost method

Hot Gas

Time to defrost 2.0 L

1.5 Hours

Vacuum pump displacement required

98 L/min or larger displacement

Plug type

North America, 230V

Power rating

230VAC, 60Hz, 12.0A, 1Ph

Dimensions (W x D x H)

28.5 x 28 x 28 in

 

Need Assistance? We're Happy to Help! 

  1. Live chat with us by clicking on the icon at the lower right of your screen.
  2. Email us at cs@newlifescientific.com
  3. Call us at (567)-210-2838

 

Estimate Shipping

Labconco FreeZone Triad Stoppering Tray Freeze Dryer/Lyophilizer

Payment & Security
  • American Express
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

READY TO BUY OR SELL USED LAB EQUIPMENT?

We can help. In addition to selling lab equipment, we also purchase it.

Contact us below for immediate service.

Ask a Question or Request a quote!