Used Beckman Avanti J-25/J-25I High-Speed Refrigerated Floor Centrifuge

Warranty

  • Includes a 90-Day warranty
  • Inquire for Warranty Upgrade Availability

QUALITY ASSURED BY NLS TECH STAFF

Specs Below

Overview of Used Beckman Coulter Avanti J-25/J-25I Refrigerated Floor Centrifuge

The Avanti J-25 and J-25I floor centrifuges support high-speed, high-volume separations. New Life Scientific provides used Avanti J-25/J-25I floor centrifuges tested and verified by our in-house technicians and warrantied for your confidence.

View in stock used floor centrifuge for sale here. Need assistance? Get in touch with us today.

Beckman Coulter Avanti J-25/J-25I Features

The Beckman Avanti J-25/J-25I floor centrifuge accommodates a variety of Beckman Coulter rotors, including fixed-angle and swinging-bucket configurations for diverse sample types.

Notable features include:

  • Durable induction motor: The J-25I's brushless design eliminates the carbon brushes that require periodic replacement in other centrifuge models, delivering lower maintenance costs and extended operational lifespan.
  • Expanded temperature range: The unit refrigerates down to minus 20° Celsius, protecting heat-sensitive proteins, enzymes and biological samples during extended runs.
  • Microprocessor-controlled operation: Store up to 30 custom run programs with the Avanti J-25I model and recall your speed, time and temperature parameters instantly, saving time and reducing operator error.
  • High-capacity rotor versatility: The system accommodates rotors from 1 to 6 liters, letting you process samples of varying sizes without switching instruments.

Beckman Coulter Avanti J-25/J-25I Floor Centrifuge Specifications

Review the detailed technical specifications for the Avanti J-25/J-25I series below:


Avanti J-25

Avanti J-25I

Manufacturer

Beckman Coulter

Beckman Coulter

Model

Avanti J-25

Avanti J-25

Speed range

100 to 25,000 rpm

100 to 25,000 rpm

Setting range

in 100-rpm increments below 10,000 rpm
in 500-rpm increments above 10,000 rpm or equivalent rcf (in 100 x g increments)

in 100-rpm increments below 10,000 rpm
in 500-rpm increments above 10,000 rpm or equivalent rcf (in 100 x g increments)

Speed display

from 0 to 10,000 rpm, indicates actual rotor speed ±10 rpm

from 10,000 to 25,000 rpm, indicates actual rotor speed ± 0.1%, or equivalent rcf

from 0 to 10,000 rpm, indicates actual rotor speed ±10 rpm

from 10,000 to 25,000 rpm, indicates actual rotor speed ± 0.1%, or equivalent rcf

Time setting range

to 180 min or continuous (hold)

to 180 min or continuous (hold)

Time display

indicates run time remaining (timed run) or elapsed time (hold run)

indicates run time remaining (timed run) or elapsed time (hold run)

Temperature setting range

-20° to +40° Celsius (in 1° Celsius increments)

-20 to +40° Celsius (in 1° Celsius increments)

Rotor temperature

±2° Celsius of set temperature (after equilibration)

±2° Celsius of set temperature (after equilibration)

Ambient temperature range

16° to 38° Celsius (60° to 100° Fahrenheit)

16° to 38° Celsius (60° to 100° Fahrenheit)

Acceleration

Maximum or slow

Maximum or slow

Deceleration

Maximum, slow, or off

Maximum, slow, or off

Power rating

200/208/240V, 50/60Hz, 24A

200/208/240V, 50/60Hz, 24A

Dimensions (W x D x H)

28 x 34 x 45.5 in

28 x 34 x 45.5 in

Weight

583 lb (264.5 kg)

583 lb (264.5 kg)

 

Our Centrifuge Testing Process

To assure the highest quality and offer a fair warranty on our products, our technicians put every product through rigorous testing:

  1. The centrifuge technician pre-tests the unit’s speed, sometimes to maximum speed for a few minutes, whether it spins up and down properly, the refrigeration, buttons, switches and timers. The technician also orders the necessary parts for repair.
  2. Once the unit’s parts arrive or are working, the centrifuge technician performs any necessary repairs.
  3. The centrifuge technician runs the unit to maximum RPMs for a minimum of one hour while observing the refrigeration performance (if applicable). During this step, loud or unusual noises, smells, and extra heat build up are observed.
  4. The centrifuge technician also observes the proper performance of sensors, including temperature, vacuum (if equipped), rotor sensors, tach sensors and latch sensors.
  5. After a full hour's run, the centrifuge technician takes a photo of the centrifuge display, which is included in the listing photos.
  6. The centrifuge technician then thoroughly inspects the centrifuge to identify anything missing, loose, or damaged. At this time, the technician follows New Life Scientific’s Centrifuge Technician Checklist to ensure everything is checked accordingly.
  7. The refrigeration condenser and chassis are cleaned by blowing out the unit with compressed air or dry ice blasting.
  8. Sensors are cleaned and/or reinstalled with the proper gap. Electrical connections are latched and tightened down properly, ensuring they have a proper power cable.
  9. Technicians check the drive mounts, drive brushes, and gas springs and replace them if necessary.
  10. Each centrifuge then gets cleaned and painted, if needed, to make the unit presentable and workplace-ready.

Our Centrifuge Technician Checklist

At New Life Scientific, our technicians test each device thoroughly before shipping to verify performance and functionality. After completing rigorous testing, the technician records key information gathered throughout the repair process by filling out the Centrifuge Technician ChecklistThe checklist will be publicly available after the centrifuge has undergone tech completion.

Beckman Coulter Avanti J-25/J-25I Floor Centrifuge Applications

The Avanti J-25/J-25I supports labs across a range of industries that require capacity and temperature stability, such as:

  • Bioprocessing: Harvesting large cell cultures in pilot-scale production, handling the throughput demands of small-batch manufacturing for biologics and vaccines
  • Protein purification and enzymology: Maintaining sample integrity during fractionation and concentration steps where temperature-labile proteins and enzymes risk thermal degradation
  • Clinical and reference labs: High-throughput processing of blood components where protocol standardization reduces variability in diagnostic workflows
  • Pharmaceutical quality control: Validating repeatable performance required for GMP compliance in pharmaceutical manufacturing environments that test raw materials and finished products
  • General research: Subcellular fractionation, nucleic acid precipitation and organelle isolation across changing experimental needs

Contact New Life Scientific Today for Additional Information

Equip your lab with a dependable floor centrifuge. Contact us today to inquire about our used Avanti J-25/J-25I floor centrifuge for sale. Our team can help you explore and choose between the J-25 and the J-25I model. You may also:


Estimate Shipping

Used Beckman Avanti J-25/J-25I High-Speed Refrigerated Floor Centrifuge

Payment & Security
  • American Express
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

READY TO BUY OR SELL USED LAB EQUIPMENT?

We can help. In addition to selling lab equipment, we also purchase it.

Contact us below for immediate service.

Ask a Question or Request a quote!