- Product Shelves
- PC with Lyos 2.0 Control Software Installed with 21CFR11 Controls Option
- Edwards nXDS15i Dry Scroll Vacuum Pump
- Corrosive-resistant Glass Door
- Trays
- Vials
- Original Factory Crate
- Cart for Computer
- Printer
- 208-230VAC Power Cable
- 90-Day to 1-Year Warranty
Our Freeze Dryer Technician Checklist
After our freeze dryer technician finishes the initial testing process, this Freeze Dryer Technician Checklist is filled out to record the important information gathered throughout the repair process. This checklist will be available publicly after the unit has undergone tech completion and is ready for the customers.
VirTis Genesis 25 EL Pilot Freeze Dryer Applications
- Biopharmaceutical Labs - Labs involved in the production of biologics, including monoclonal antibodies, therapeutic proteins, and peptides, use freeze dryers to stabilize and preserve these sensitive products.
- Vaccine Development Labs - Labs working on vaccine production, especially those requiring lyophilization to preserve the potency of live or inactivated viruses, often rely on freeze-drying.
- Gene and Cell Therapy Labs - Labs focused on gene therapies (e.g., plasmids, mRNA) and cell therapy (e.g., stem cells) use freeze dryers to preserve the viability and stability of biological materials.
- Diagnostic and Assay Labs - Laboratories producing diagnostic kits, reagents, and assays, especially for long-term storage and stability, use freeze dryers to maintain their integrity over time.
- Research and Biotech Labs - Labs involved in biological research, including the preservation of biological samples, cell lines, and microbial cultures, use freeze dryers for sample storage and transportation.
- Blood Bank and Plasma Labs - Labs that process and store blood plasma, serum, and other biological materials often use freeze dryers to maintain the stability of these sensitive components.
- Nutraceutical and Exosome Therapy Labs - Labs producing nutraceuticals (e.g., probiotics) or exosome-based therapies use freeze dryers to stabilize these products for longer shelf life.
We can provide installation and IQ/OQ verification for this system. Please contact us for scheduling and pricing if you have need of these services.
Manufacturer
|
SP Scientific
|
Model
|
25L Genesis EL-85°
|
Lowest shelf temperature (50Hz/60Hz)
|
≤ -67°C / -70°C
|
Shelf temperature control range
|
-55°C to 65°C
|
Shelf pull-down from 20°C to -40°C
|
≤ 30 minutes
|
Lowest condenser temperature (50Hz/60Hz)
|
≤ -82°C / -85°C
|
Maximum condenser capacity
|
≥ 25 L
|
Condenser surface area
|
506 in2 (3,264 cm2)
|
Condenser pull-down from 20°C to -45°C
|
≤ 25 minutes
|
Maximum ice condensing capacity in 24 hours
|
≥ 12 L
|
Maximum deposition rate
|
≥ 0.5 L/hour
|
Number of compressors
|
2
|
Compressor horsepower
|
1 hp, 1 hp
|
Vacuum time to 100 millitorr
|
≤ 20 minutes
|
Vacuum rate of rise
|
≤ 30 mT/hour
|
Volume-based leak rate
|
≤ .0016 mbar⦁L/sec
|
Lowest system vacuum
|
≤ 15 mT
|
Temperature uniformity
|
± 1.0°C
|
Dimensions (W x D x H)
|
40 x 30 x 79.3 in (102 x 76 x 201.4 cm)
|
Weight
|
800 lb (362.9 kg)
|
Minimum clearance on all sides
|
10 in (25 cm)
|
Note: Performance specifications are based on SP test data from units operating at an ambient room temperature of approximately 20°C. SP recommends an optimum operating range of 15-25°C (59-77°F)
Note: SP recommends a 24-inch (61 cm) clearance around all sides of the unit for serviceability. If machines are placed side by side, increase the minimum clearance to 48 inches (121.9 cm)
Compressed air (for units with isolation valve)
|
80 psig (6.5 bar)
|
Ambient room temperature
|
15-25°C (59-77°F)
|
Approx. peak room heat generated (air-cooled units)
|
10,200 BTU/h (3.0 kW)
|
Approx. peak room heat generated (water-cooled units)
|
4,100 BTU/h (1.2 kW)
|
Cooling water usage
|
1-3 gpm (4-12 LpM)
|
Cooling water load
|
6,100 BTU/hr (1.8 kW)
|
Voltage
|
Phase
|
Hertz
|
Breaker Amperage
|
Recommended Outlet
|
208-230VAC
|
1
|
60
|
30A
|
NEMA L6-30R
|
|
|
EL
|
|
Gas 1
|
Gas 2
|
F gas
|
R407C
|
R508B
|
Charge (Kg)
|
1.019 (AC); 0.509 (WC)
|
0.343
|
GWP
|
1774
|
13396
|
EPA SNAP
|
IPR/VLTR
|
IPR/VLTR
|
Safety Class
|
A1
|
A1
|
Total CO2e (t)
|
6.403 (AC); 5.498 (WC)
|
6.403 (AC); 5.498 (WC)
|